Icom IC-7000 User Manual
Page 124
115
9
SCAN OPERATION
qSelect VFO mode, then set a frequency.
wClose the squelch with [RF/SQL].
eSet the desired memory channel as the watching
channel.
rSelect S
-
2.
tPush [F-2 PRI] to start the priority watch.
• “
” appears and decimal point blink while scanning.
yWhen the scan detects a signal, the scan pauses
for 10 sec. or until the signal disappears, depend-
ing on the resume setting.
uTo cancel the scan push [F-2 PRI].
NOTE: The paused condition when detecting a sig-
nal diff
ers depending on the scan resume condi-
tion. (p 134)
resume on: pauses for 10 sec.
resume off: pauses until the signal disappears.
Select
VFO mode.
Select watching
channel.
Push [F-2 PRI].
[MENU/GRP] [F-2]
[RF/SQL]
Appears while scanning
qSelect S
-
2.
wPush [F-3 V/M] to select memory mode.
eClose the squelch with [RF/SQL].
rPush [F-1 SCN] to start the memory scan.
•
Decimal point blinks while scanning.
tPush [F-2 SEL] to change the memory scan to se-
lect memory scan.
yWhen the scan detects a signal, the scan stops or
pauses depending on the resume setting.
uTo cancel the scan push [F-1 SCN].
NOTE: Two or more memory channels must be
designated as select m
emory channels for select
memory scan to start (see p. 106).
While scan function is not activate, pushing
[F-2
SEL
]
sets the select memory channels ON or OFF.
And pushing and holding
[F-2 SEL] for 2 sec.
clears the all select memory channels
.
Designate
“
★.”
Select
memory mode.
Push [F-1 SCN],
then push [F-2 SEL].
[MENU/GRP] [F-1] [F-2] [F-3]
[RF/SQL]
■Select memory scan operation
■Priority watch
Menu group selection
Push
[MENU/GRP] for 1 sec.
Selection from: M, S or G(Graphic)
Menu selection (Example: M)
Push
[MENU/GRP] momentarily.
Selection from: S
-
1
, S
-
2
or S
-
3
Either
Y or Z
Either
Y
or
Z