25 * its: define properties for its elements, Required parameter, Data line for itsuni elements – ABAQUS Volume II: I–Z User Manual
Page 93: Data line for itscyl elements

*ITS
9.25
*ITS:
Define properties for ITS elements.
This option is used to define the properties for ITS-type elements. The *DASHPOT, *FRICTION, and
*SPRING options must immediately follow this option.
Product:
ABAQUS/Standard
Type:
Model data
Level:
Part, Part instance
References:
•
“Rigid surface contact elements,” Section 31.5.1 of the ABAQUS Analysis User’s Manual
•
*DASHPOT
•
*FRICTION
•
*SPRING
Required parameter:
ELSET
Set this parameter equal to the name of the element set containing the ITS-type elements for which
properties are being defined.
Data line for ITSUNI elements:
First (and only) line:
1. Tube outside diameter.
2. Distance between the parallel support plates on opposite sides of the tube.
3. X-direction cosine of the axis of the tube.
4. Y-direction cosine of the axis of the tube.
5. Z-direction cosine of the axis of the tube.
6. X-direction cosine of the normal to either one of the support plates.
7. Y-direction cosine of the normal to either one of the support plates.
8. Z-direction cosine of the normal to either one of the support plates.
Data line for ITSCYL elements:
First (and only) line:
1. Tube outside diameter.
9.25–1