Optional parameters, Data lines to define surface radiation conditions – ABAQUS Volume II: I–Z User Manual
Page 459

*SRADIATE
18.30
*SRADIATE:
Specify surface radiation conditions in heat transfer analysis.
This option is used to apply surface radiation boundary conditions between a nonconcave surface and a
nonreflecting environment in fully coupled thermal-stress analysis. In ABAQUS/Standard it is also used
for heat transfer and coupled thermal-electrical analyses.
It must be used in conjunction with the *PHYSICAL CONSTANTS option, which is used to define the
Stefan-Boltzmann constant.
Products:
ABAQUS/Standard
ABAQUS/Explicit
Type:
History data
Level:
Step
Reference:
•
“Thermal loads,” Section 27.4.4 of the ABAQUS Analysis User’s Manual
Optional parameters:
AMPLITUDE
Set this parameter equal to the name of the *AMPLITUDE option that gives the variation of the
ambient temperature with time.
If this parameter is omitted in an ABAQUS/Standard analysis, the reference magnitude is
applied immediately at the beginning of the step or linearly over the step, depending on the value
assigned to the AMPLITUDE parameter on the *STEP option (see “Procedures: overview,”
Section 6.1.1 of the ABAQUS Analysis User’s Manual).
If this parameter is omitted in an
ABAQUS/Explicit analysis, the reference magnitude is applied immediately at the beginning of
the step.
OP
Set OP=MOD (default) for existing *SRADIATE definitions to remain, with this option modifying
existing radiation conditions or defining additional radiation conditions.
Set OP=NEW if all existing *SRADIATE definitions applied to the model should be removed.
Data lines to define surface radiation conditions:
First line:
1. Surface name.
2. Radiation type label R.
3. Reference ambient temperature value,
. (Units of .)
18.30–1
ABAQUS Version 6.1
Module: ID:
Printed on: