Optional parameter, Data lines to specify creep test data, Data lines to specify relaxation test data – ABAQUS Volume II: I–Z User Manual
Page 413

*SHEAR TEST DATA
18.13
*SHEAR TEST DATA:
Used to provide shear test data.
This option can be used only in conjunction with the *VISCOELASTIC option. The *SHEAR TEST DATA
option cannot be used for a viscoelastic material if the *COMBINED TEST DATA option is used.
Products:
ABAQUS/Standard
ABAQUS/Explicit
Type:
Model data
Level:
Model
Using shear test data to define a viscoelastic material
References:
•
“Time domain viscoelasticity,” Section 17.7.1 of the ABAQUS Analysis User’s Manual
•
*VISCOELASTIC
Optional parameter:
SHRINF
To specify creep test data, set this parameter equal to the value of the long-term, normalized shear
compliance
.
To specify relaxation test data, set this parameter equal to the value of the long-term,
normalized shear modulus
.
The shear compliance and shear modulus are related by
.
The fitting procedure will use the specified value in the constraint
.
Data lines to specify creep test data:
First line:
1. Normalized shear compliance
.
2. Time t.
Repeat this data line as often as necessary to give the compliance-time data.
Data lines to specify relaxation test data:
First line:
1. Normalized shear relaxation modulus
.
2. Time t.
Repeat this data line as often as necessary to give the modulus-time data.
18.13–1
ABAQUS Version 6.1
Module: ID: