beautypg.com

Data line to define the joule heat fraction – ABAQUS Volume II: I–Z User Manual

Page 109

background image

*JOULE HEAT FRACTION

10.5

*JOULE HEAT FRACTION:

Define the fraction of electric energy released as heat.

This option is used to specify the fraction of dissipated electrical energy released as heat in coupled thermal-
electrical problems.

Product:

ABAQUS/Standard

Type:

Model data

Level:

Model

Reference:

“Coupled thermal-electrical analysis,” Section 6.6.2 of the ABAQUS Analysis User’s Manual

There are no parameters associated with this option.

Data line to define the joule heat fraction:

First (and only) line:

1. Fraction of electrical energy released as heat, including any unit conversion factor. The default

value is 1.0.

10.5–1

ABAQUS Version 6.1

Module: ID:

Printed on: