Data line to define the joule heat fraction – ABAQUS Volume II: I–Z User Manual
Page 109
*JOULE HEAT FRACTION
10.5
*JOULE HEAT FRACTION:
Define the fraction of electric energy released as heat.
This option is used to specify the fraction of dissipated electrical energy released as heat in coupled thermal-
electrical problems.
Product:
ABAQUS/Standard
Type:
Model data
Level:
Model
Reference:
•
“Coupled thermal-electrical analysis,” Section 6.6.2 of the ABAQUS Analysis User’s Manual
There are no parameters associated with this option.
Data line to define the joule heat fraction:
First (and only) line:
1. Fraction of electrical energy released as heat, including any unit conversion factor. The default
value is 1.0.
10.5–1
ABAQUS Version 6.1
Module: ID:
Printed on: