Required parameters, Optional parameter – ABAQUS Volume II: I–Z User Manual
Page 167

*MONITOR
13.20
*MONITOR:
Define a degree of freedom to monitor.
This option is used to choose a node and degree of freedom to monitor the progress of the solution in the
status file. In ABAQUS/Standard the information will also be written to the message file.
Products:
ABAQUS/Standard
ABAQUS/Explicit
Type:
History data
Level:
Step
Reference:
•
“Output,” Section 4.1.1 of the ABAQUS Analysis User’s Manual
Required parameters:
DOF
Set this parameter equal to the degree of freedom to be monitored at the node.
In an
ABAQUS/Explicit analysis the degree of freedom will be in the global coordinate system. If
the *TRANSFORM option is used at the node in an ABAQUS/Standard analysis, the degree of
freedom is in the local, transformed, system.
NODE
Set this parameter equal to either the node number to be monitored or the name of a node set
containing the node to be monitored. If the name of a node set is chosen, the node set must contain
exactly one node.
Optional parameter:
FREQUENCY
This parameter applies only to ABAQUS/Standard analyses.
This parameter will only affect output to the message file. Set this parameter equal to the output
frequency in increments. The output will always be printed at the last increment of each step unless
FREQUENCY=0. The default is FREQUENCY=1. Set FREQUENCY=0 to suppress the output.
There are no data lines associated with this option.
13.20–1
ABAQUS Version 6.1