beautypg.com

Required parameter, Required, mutually exclusive parameters – ABAQUS Volume II: I–Z User Manual

Page 309

background image

*PRE-TENSION SECTION

16.27

*PRE-TENSION SECTION:

Associate a pre-tension node with a pre-tension section.

This option is used to associate a pre-tension node with a pre-tension section.

Product:

ABAQUS/Standard

Type:

Model data

Level:

Part, Part instance, Assembly

Reference:

“Prescribed assembly loads,” Section 27.5.1 of the ABAQUS Analysis User’s Manual

Required parameter:

NODE

Set this parameter equal to either the pre-tension node number or the name of a node set containing
the pre-tension node. If the name of a node set is chosen, the node set must contain exactly one
node.

Required, mutually exclusive parameters:

ELEMENT

Set this parameter equal to either the element number of the truss or beam element used to define
the pre-tension section or the name of an element set containing the truss or beam element used to
define the pre-tension section. If the name of an element set is chosen, the element set must contain
exactly one element.

SURFACE

Set this parameter equal to the name of the surface definition (*SURFACE) that defines the pre-
tension section (when continuum elements are used).

Data line to define the normal to the section (optional):

First (and only) data line:

1. First component of the normal.

2. Second component of the normal.

3. Third component of the normal.

16.27–1

ABAQUS Version 6.1

Module: ID:

Printed on: