Optional parameters – ABAQUS Volume II: I–Z User Manual
Page 317

*RADIATE
17.1
*RADIATE:
Specify radiation conditions in heat transfer analyses.
This option is used to apply radiation boundary conditions between a nonconcave surface and a nonreflecting
environment in fully coupled thermal-stress analysis. In ABAQUS/Standard it is also used for heat transfer
and coupled thermal-electrical analyses.
It must be used in conjunction with the *PHYSICAL CONSTANTS option, which is used to define the
Stefan-Boltzmann constant.
Products:
ABAQUS/Standard
ABAQUS/Explicit
Type:
History data
Level:
Step
Reference:
•
“Thermal loads,” Section 27.4.4 of the ABAQUS Analysis User’s Manual
Optional parameters:
AMPLITUDE
Set this parameter equal to the name of the *AMPLITUDE option that gives the variation of the
ambient temperature with time.
If this parameter is omitted in an ABAQUS/Standard analysis, the reference magnitude is
applied immediately at the beginning of the step or linearly over the step, depending on the value
assigned to the AMPLITUDE parameter on the *STEP option (see “Procedures: overview,”
Section 6.1.1 of the ABAQUS Analysis User’s Manual).
If this parameter is omitted in an
ABAQUS/Explicit analysis, the reference magnitude given on the data lines is applied throughout
the step.
OP
Set OP=MOD (default) for existing *RADIATE definitions to remain, with this option modifying
existing radiation conditions or defining additional radiation conditions.
Set OP=NEW if all existing *RADIATE definitions applied to the model should be removed.
REGION TYPE
This parameter applies only to ABAQUS/Explicit analyses.
This parameter is relevant only for radiation conditions applied to the boundary of an adaptive
mesh domain. If a radiation condition is applied to a surface in the interior of an adaptive mesh
domain, the nodes on the surface will move with the material in all directions (they will be
nonadaptive).
ABAQUS/Explicit will create a boundary region automatically on the surface
subjected to the defined radiation condition.
17.1–1
ABAQUS Version 6.1
Module: ID: