ABAQUS Volume II: I–Z User Manual
Page 465

*STEADY STATE CRITERIA
18.32
*STEADY
STATE
CRITERIA:
Specify
steady-state
criteria
for
terminating
a
quasi-static uni-directional simulation.
This option is used to specify the norms that must be satisfied to halt a quasi-static uni-directional simulation
based on achieving a steady-state condition. It must be used in conjunction with the *STEADY STATE
DETECTION option.
Product:
ABAQUS/Explicit
Type:
History data
Level:
Step
References:
•
“Steady-state detection,” Section 11.8.1 of the ABAQUS Analysis User’s Manual
•
“Output to the output database,” Section 4.1.3 of the ABAQUS Analysis User’s Manual
•
*STEADY STATE DETECTION
There are no parameters associated with this option.
Data lines to define steady-state detection norms SSPEEQ and SSSPRD:
First line:
1. Norm type.
2. Norm tolerance. The default tolerance is .001.
3. Global X-coordinate of a point on the exit plane.
4. Global Y-coordinate of a point on the exit plane.
5. Global Z-coordinate of a point on the exit plane.
Repeat this data line as often as necessary. Each line defines a criterion that must be satisfied to achieve
steady state.
Data lines to define steady-state detection norms SSFORC and SSTORQ:
First line:
1. Norm type.
2. Norm tolerance. The default tolerance is .005.
3. Global X-coordinate of a point on the exit plane.
4. Global Y-coordinate of a point on the exit plane.
5. Global Z-coordinate of a point on the exit plane.
6. Rigid body reference node number.
18.32–1
ABAQUS Version 6.1
Module: ID:
Printed on: