Data line to define the wind velocity profile – ABAQUS Volume II: I–Z User Manual
Page 627

*WIND
22.2
*WIND:
Define wind velocity profile for wind loading.
This option is used to define a wind velocity profile for use in applying loads.
Product:
ABAQUS/Aqua
Type:
Model data
Level:
Model
Reference:
•
“ABAQUS/Aqua analysis,” Section 6.10.1 of the ABAQUS Analysis User’s Manual
There are no parameters associated with this option.
Data line to define the wind velocity profile:
First (and only) line:
1. Air density,
.
2. Reference height for wind profile,
.
3. Local x-direction velocity constant,
(default value 1.0).
4. Local y-direction velocity constant,
(default value 1.0).
5. x-direction cosine defining the direction of the unit vector (the wind local x-axis) with respect
to the global coordinate system. In three-dimensional cases both x- and y-components are
needed; in two-dimensional cases only the x-component is used.
6. y-direction cosine defining the direction of the unit vector (the wind local x-axis) with respect
to the global coordinate system. This component is not needed in two-dimensional cases.
7.
(default value 1/7).