18

.

Disconnect the fingerprint reader board cable (1) from the fingerprint reader board.

19

.

If it is necessary to replace the fingerprint reader board, remove the Phillips PM2.0×4.0 screw (2)

that secures the fingerprint reader board and bracket to the display bezel.

20

.

Remove the fingerprint reader board bracket (3).

21

.

Lift the left side of the fingerprint reader board (4) and remove the board from the display bezel.

NOTE:

The fingerprint reader board and bracket are available using spare part number

441121-001.

22

.

If it is necessary to replace the display inverter, remove the Phillips PM2.0×4.0 screw (1) that secures

the inverter to the display enclosure.

23

.

Disconnect the backlight cable (2) and the display panel cable (3) from the inverter.

24

.

Remove the display inverter (4).

NOTE:

The display inverter is available using spare part number 441119-001.

ENWW

Component replacement procedures 57