beautypg.com

Specifications 57 – Emerson 400518-01 User Manual

Page 69

background image

Specifications

57

Safety Information

Product Overview

Installation

Diagnostics

Options and
Accessories

Specification

Fault Detection Capability

Low DC bus (can be disabled)
High DC bus
Power Stage fault
Logic power
Encoder state
Encoder line break
Drive overtemperature
Motor overtemperature
Overspeed
Travel limit (+)
Travel limit (-)
Following error
Power-up self test failure
Non-volatile memory invalid

Cooling Method

EP202, EP204, EP206: Natural Convection

Environmental

Pollution degree 2 environment, Maximum surrounding air temperature: 40°C full rating,
50°C with derating
Minimum operating temperature: 0°C
Storage Temperature: -25°C to 75°C
Rated Altitude: 3250 ft [1000 m]
Higher Altitude: Derate output current; 1% / 100m above 1000m
Humidity: 10% to 95% - non-condensing
Vibration: 2g, 10 Hz to 2000 Hz

Standards and Agency Approvals

UL listed
Canadian UL listed
CE Mark: Low voltage directive; EMC directive

Drive Weights

EP202-B, -I, -IDN 3.6 lb (1.63 kg)
EP204-B, I, -IDN 3.6 lb (1.63 kg)
EP206-B, -I, -IDN 4.2 lb (1.91 kg)
EP202-P 3.9 lb (1.77 kg)
EP204-P 3.9 lb (1.77 kg)
EP206-P 4.5lb (2.04 kg)

Epsilon EP Series