Step 4: low power connections, Dc logic power supply wiring, Front view – Emerson 400518-01 User Manual
Page 34: Logic power supply specification, Figure 19: logic power supply wiring diagram
22
Safety Information
Product Overview
Installation
Diagnostics
Options and
Accessories
Specification
Step 4: Low Power Connections
DC Logic Power Supply Wiring
The Epsilon drive requires a user supplied logic power supply, 24 Vdc ±10%, to power the internal logic of the drive.
Use the table below to determine the current requirements of the application. Users should consider keeping logic
power energized at all times because it helps prevent condensation and maintains position information in the drive.
Logic Power Supply Specification
Figure 19:
Logic Power Supply Wiring Diagram
For UL applications, the logic power supply must be a UL recognized or UL listed limited voltage/limited energy or
limited voltage/limited current supply, or a limited voltage supply with overcurrent protection appropriate for the wiring
and not to exceed 12 A. Isolate line connected circuits from low voltage circuits.
For applications to meet the EU Low Voltage Directive, an approved 24V supply must be used and the negative side
must be grounded to PE. PELV circuits must have protective separation for 300 V system voltage from mains
connected circuits, including separation between encoder circuits and motor power wiring. If all circuits connected
Voltage Range
Model
Current
24 Vdc ±10%
(21.6 Vdc to 26.4 Vdc)
EP-P
050 A without sync encoder
0.57 A with 250 mA sync encoder
All EP Models except EP-P
0.31 A without sync encoder
0.38 A with 250 mA sync encoder
Do not wire AC line into the logic power supply input. Doing so will damage the drive.
24 Vdc
Logic Power Supply
(User Supplied)
24 Vdc
24 V RTN
EP204-I00-0000
9606XX-XX A1
SN 0610E014
Front View
Single point PE ground
To other drives or equipment , I/O supplies, etc..
Tighten screws
to 5 in-lb.
motor
logic
+
_
L1
L2
PE
R
S
T
motor
logic
+
_
L1
L2
PE
R
S
T
Fuse, if required
to protect wiring