Step 4: Low Power Connections

DC Logic Power Supply Wiring

The Epsilon drive requires a user supplied logic power supply, 24 Vdc ±10%, to power the internal logic of the drive.

Use the table below to determine the current requirements of the application. Users should consider keeping logic

power energized at all times because it helps prevent condensation and maintains position information in the drive.

Logic Power Supply Specification

Figure 19:

Logic Power Supply Wiring Diagram

For UL applications, the logic power supply must be a UL recognized or UL listed limited voltage/limited energy or

limited voltage/limited current supply, or a limited voltage supply with overcurrent protection appropriate for the wiring

and not to exceed 12 A. Isolate line connected circuits from low voltage circuits.
For applications to meet the EU Low Voltage Directive, an approved 24V supply must be used and the negative side

must be grounded to PE. PELV circuits must have protective separation for 300 V system voltage from mains

connected circuits, including separation between encoder circuits and motor power wiring. If all circuits connected

Voltage Range

Model

Current

24 Vdc ±10%

(21.6 Vdc to 26.4 Vdc)

EP-P

050 A without sync encoder

0.57 A with 250 mA sync encoder

All EP Models except EP-P

0.31 A without sync encoder

0.38 A with 250 mA sync encoder

Do not wire AC line into the logic power supply input. Doing so will damage the drive.

24 Vdc

Logic Power Supply

(User Supplied)

24 Vdc
24 V RTN

EP204-I00-0000
9606XX-XX A1
SN 0610E014

Front View

Single point PE ground

To other drives or equipment , I/O supplies, etc..

Tighten screws

to 5 in-lb.

motor

logic

+
_

L1

L2

PE

R

S

T

motor

logic

+
_

L1

L2

PE

R

S

T

Fuse, if required