Emerson 400518-01 User Manual
Page 45
Installation
33
Safety Information
Product Overview
Installation
Diagnostics
Options and
Accessories
Specification
Figure 35:
Analog/Sync Output Connector (J5) Encoder Output Wiring
Figure 36:
Direction Convention Diagram
If the external controller does not have an internal terminating resistor
R1, R2 and R3 must be mounted within 3 ft [1 m] of the external controller. A
120 ohm resistor is recommended for high frequency encoders (over 250 kHz)
or cables longer than 25 feet. If encoder signals are multi-dropped, termination
resistors are required only at the last drop point. Do not terminate at more than
one point.
Note:
R1
R2
R3
External
Controller
Encoder
Input
= Twisted Pair
Single Point
PE Ground
PE
Drive (J5)
1
9
2
10
3
11
A
A/
B
B/
Z
Z/
A
A/
B
B/
Z
Z/
Connector Shell
Internal
10 Ohm