STI-24IO

The STI-24IO interface board allows access to all digital input and output signals. The STI-24IO mounts directly to

the digital I/O connector (J3) on the front of the EP drive. See figure 47 below.

Shield connection points are connected to the shell of the 26 pin “D” connector on the STI-24IO.

The STI-24IO wire range is #18 to 24 AWG stranded insulated wire.

Wiring should be done with consideration for future troubleshooting and repair. All wiring should be either color
coded and/or tagged with industrial wire tabs. Low voltage wiring should be routed away from high voltage wiring.

Figure 47:

Dimensions of the STI-24IO Board

Do not allow ESD directly to terminals. Always discharge static electricity to enclosure, not the drive when
performing maintenance.

+24V

0V

0

1

2

3

4

5

6

7

TB1

TB2

TB4

TB3

OUTPUTS

1

2

3

4

5

6

7

8

INPUTS

EN

8

9

10

11

12

13

14

15

3.2

2.1