Input/output and drive enable wiring – Emerson 400518-01 User Manual
Page 38
26
Safety Information
Product Overview
Installation
Diagnostics
Options and
Accessories
Specification
Figure 24:
Epsilon EP/XV 40-80 mm Motor Brake Wiring Diagram
Figure 25:
Epsilon EP/XV 130 mm Motor Brake Wiring Diagram using the I/O
Connector
Input/Output and Drive Enable Wiring
The Epsilon EP-B drive is equipped with 5 optically isolated input lines (one is dedicated to a drive enable function)
and 3 optically isolated output lines. The Epsilon EP-I, EP-IDN and EP-P drives are equipped with 16 optically
isolated input lines (one is dedicated to a drive enable function) and 8 optically isolated output lines. All inputs and
outputs are configured as sourcing; that is, the outputs "source" current from the positive side of the I/O supply when
ON and the inputs are compatible with a sourcing output returning current to the grounded negative side of the I/O
supply.
EP204-I00-0000
9606XX-XX A1
SN 0610E014
motor
logic
+
_
L1
L2
PE
R
S
T
digital i/o (J3)
Output #3
Drive Enable
I/O Common
I/O Supply
J3
-
+
Internal
to Motor
Red +
Black -
Connected to
grounded
mounting panel.
Single point
PE ground
2 Amp
Fuse
Customer
supplied drive
enable contact
24 VDC
XV 40mm-80mm
Motor
1 Amp
Fuse
XTBMS-xxx Cable
19
10
8
20
11
A2
14
A1
Relay:
Model# BRM-1
K1
A
C
B
EP204-I00-0000
9606XX-XX A1
SN 0610E014
motor
logic
+
_
L1
L2
PE
R
S
T
digital i/o (J3)
Output #3
Drive Enable
I/O Common
I/O Supply
J3
-
+
Internal to Motor
Blu +
Blue/Wht -
-
Single point
PE ground
2 Amp
Fuse
Customer
supplied drive
enable contact
24 VDC
XV 130mm
Motor
1 Amp
Fuse
XCMDBS-xxx Cable
19
10
8
20
11
A2
14
A1
Relay:
Model# BRM-1
K1
A
F
E
D
B
C