beautypg.com

Emerson 400518-01 User Manual

Page 48

background image

36

Safety Information

Product Overview

Installation

Diagnostics

Options and
Accessories

Specification

Figure 41:

Pulse/Pulse Mode, Single Ended Output to Single Ended Input (non-twisted

pair cable)

Figure 42:

Master/Slave Encoder Connections

Encoder outputs meet RS-422 driver specifications and can drive up to 10 RS-422 signal receivers. Each
differential pulse input is an RS-422 line receivers. The default encoder output resolution is 2048 lines per
motor revolution. This resolution is adjustable in one line per revolution increments with PowerTools Pro
software. The range is between 1 and the actual motor encoder density.

Common isolated from other sources

Sinking

Outputs (typ)

logic
common

PE

10
Ohm

Drive

Analog/Sync Output Connector

(J5)

CCW Pulse

CCW Pulse

Single Point
Panel Ground

CW

CCW

CW Pulse

1

µs Minimum

500 ns Minimum

1

µs Minimum

Motion occurs
on falling edge

CW Pulse

Shield connected
to connector shell

8

12

4

Pulse

Direction

R1

R2

R3

Sync Input Connector (J10)

A A/ B B/ Z Z/

1 2 3 5 6 7

Sync Input Connector (J10)

A A/ B B/ Z Z/

1 2 3 5 6 7

Slave Drive

Slave Drive

Slave Drive

A A/ B B/ Z Z/

1 2 3 5 6 7

Sync Input Connector (J10)

R1, R2, and R3 must be mounted within 3 ft [1m] of the end drive.
A 120 ohm resistor is recommended for high frequency
(over 250 kHz) stepping or cable lengths longer than 25 feet.

Note:

= Twisted Pair

RS-422
Drivers

Master Encoder
or Drive Output