Backplane configuration] section: error offset – ProSoft Technology PTQ-104S User Manual
Page 177

48TPTQ-104S Rev 1 ♦ 47TQuantum Platform
Reference
46TIEC 60870-5-104 Server for Quantum
12TUser Manual
Word Offset in Block
Data Field(s)
Description
4033
Sequence Number
Errors
This word contains the number of sequence
number errors recognized by the module. When the
send sequence number received by the module
does not match the expected sequence number,
the connection is closed and this counter is
incremented
4034
Bad Address
This word contains the number of messages
received with a wrong Common ASDU Address
value
4035
Bad Length
This word contains the number of messages
received by the host that does not contain a valid
length field
4036
Active
!0 = Yes, 0 = No.
4037
Socket State
This word contains the current socket state as
follows:
-1 = Open Socket
0 = Wait for Connection
1 = Transmit Message if Ready
2 = Receive Packet and process message
3 = Process multiple messages in packet
50 = Send TestFR ACT
51 = Wait for TestFR Con
60 = Send S-Format Message
1000 = Close Socket
1001 = Wait for Socket to Close
4038
Socket Open Count This word contains the number of times the socket
listen function was executed
4039
Socket Close
Count
This word contains the number of times the an
active close function was executed
4040
Socket Connect
Count
This word contains the number of times a
connection was established between with the
remote host unit
4041
Event Buffer 0
Event data from MSP free events
4042
Event Buffer 1
Event data from MDP free events
4043
Event Buffer 2
Event data from MST free events
4044
Event Buffer 3
Event data from MMA free events
4045
Event Buffer 4
Event data from MMB free events
4046
Reserved
Reserved
4047
Event Buffer 6
Event data from MIT free events
The module has two parameters to copy parts of the status registers to the
database as follows:
[Backplane Configuration] section: Error Offset
Word Offset in Block
Data Field(s)
Description
0
Scan Count
This status value contains a counter incremented
on each scan of the module's main loop.
1 to 2
Product Name
This two-word data area contains the text values
representing the product name.
3 to 4
Revision
This two-word data area contains the text values
for the revision number.
5 to 6
Op Sys #
This two-word data area contains the text values
for the operating system number.
ProSoft Technology, Inc.