ProSoft Technology MVI69-GEC User Manual

Page 66

background image

Contents

MVI69-GEC ♦ CompactLogix or MicroLogix Platform

User Manual

Page 66 of 86

ProSoft Technology, Inc.

February 18, 2014

Parameter

Block
Offset
Start

Description

Client[2].Connected

35

This flag defines if the client is utilized and connected to a
server. A value of 0 indicates the client is not connected and
can be utilized for a connection. Any other value indicates
the client is connected and being used.

Client[2].State

36

This flag defines the current state of the client.

Client[2].IP

37

This double-word value contains the IP address of the server
connected to the client.

Client[2].Port

39

This word value contains the port address for the server
connected to the client.

Client[2].RxCount

40

This status value contains the total number of messages
received by the client.

Client[2].RxOverflow

41

This status value contains the total number of messages
received that exceed the specified buffer size for the client.

Client[2].TxCount

42

This status value contains the total number of messages
transmitted by the client.

Client[2].TxOverflow

43

This status value contains the total number of transmit
messages that exceeded the specified maximum buffer size
for the client.

Client[2].spare

44

Reserved for future use

Reserved

45 to 57

This data area is reserved for future use.

Server States

58 to 62

State of each of the five servers.

Last Write Count

63

This word contains the number of characters written on
server from last BTR block.

If word 1 of the Input Image block is set to -4, the data for the last two clients is passed to
the processor. The format of this block is as follows:

Parameter

Block
Offset
Start

Description

Seq Number

0

Sequence number for this block.

Server Index

1

For this status data block, this word is set to a value of -4.

PassCnt

2

Program cycle counter

Product

3

Product name as ASCII string

Rev

5

Revision level as ASCII string

OP

7

Operating system level as ASCII string

Run

9

Run number as ASCII string

BlkErrs.Read

11

Number of blocks transferred from module to processor

BlkErrs.Write

12

Number of blocks transferred from processor to module

BlkErrs.Parse

13

Number of blocks parsed by module

BlkErrs.Err

14

Number of block errors in module

Client[3].Connected

15

This flag defines if the client is utilized and connected to a
server. A value of 0 indicates the client is not connected and
can be utilized for a connection. Any other value indicates
the client is connected and being used.