7 poe alive check configuration – PLANET IGS-10020HPT User Manual
Page 343
User’s Manual of IGS-10020PT / IGS-10020HPT
343
4.16.7 PoE Alive Check Configuration
The IGS-10020PT / IGS-10020HPT PoE Switch can be configured to monitor connected PD’s status in real time via ping action.
Once the PD stops working and is without response, the IGS-10020PT / IGS-10020HPT PoE Switch is going to restart PoE port
port power, and bring the PD back to work. It will greatly enhance the reliability and reduces administrator management burden.
PD Ping Alive Check Configuration
This page provides you with how to configure PD Alive Check.The screen in Figure
4-16-8
appears.
Figure 4-16-8: PD Alive Check Configuration Screenshot
The page includes the following fields:
Object
Description
• Mode
Allows user to enable or disable per port PD Alive Check function. As default value
all ports are disabled.
• Ping PD IP Address
This coulumn allows user to set PoE device IP address here for system making ping
to the PoE device. Please be noted that the PD’s IP address must be set to the
same network segment as the IGS-10020PT / IGS-10020HPT PoE Switch.
• Interval Time (10~300s)
This column allows user to set how long system should issue a ping request to PD
for detecting PD whether it is alive or dead. Interval time range is from 10 seconds to
300 seconds.