Sflow flowsampler, Sflow counterpoller – PLANET XGSW-28040 User Manual
Page 538
User’s Manual of XGSW-28040
release
: Release the current owner of the receiver.
The owner can either be "
"
else if is set-up through SNMP. You can only (re-)configure the receiver if it is not currently owned by
anyone or owned by CLI or Web. If this argument is specified, the remaining arguments are ignored.
Receiver timeout measured in seconds. The switch decrements the timeout once per second, and as
long as it is non-zero, the receiver receives samples. Once the timeout reaches 0, the receiver and all
its configuration is reset to defaults. Valid range is 0 - 2147483647 seconds.
: IPv4/IPv6 address or a hostname identifying the receiver.
: Receiver's UDP port. Valid range is 0 - 65535.
Use 0 to get default port (which is 6343).
: Maximum datagram size. Valid range is 200 - 1468 bytes.
Default is 1400 bytes.
sFlow FlowSampler
Description:
Set or show flow sampler configuration per port.
When operational, the sampling rate 'N' is rounded off to the nearest supported value.
Syntax:
sFlow FlowSampler [
Parameters:
: Port list or 'all'. Default: All ports.
: Specifies the statistical sampling rate
The sample rate is specified as N to sample 1/Nth of the packets in the monitored flows. There are no
restrictions on the value, but the switch will adjust it to the closest possible sampling rate.
0 disables sampling.
: Specifies the maximum number of bytes to transmit per flow sample.
Valid range is 14 - 200 bytes. Default: 128 bytes.
sFlow CounterPoller
Description:
Set or show counter polling interval configuration per port.
Syntax:
538