beautypg.com

Table 4.7 diffsens scsi signal, Diffsens scsi signal – Avago Technologies LSI53C320 User Manual

Page 46

background image

4-4

Specifications

Version 2.2

Copyright © 2003 by LSI Logic Corporation. All rights reserved.

Table 4.5

Bidirectional SCSI Signals

SD[15:0]/, SDP[1:0]/,

SREQ/, SACK/, SD[15:0]

±

, SDP[1:0]

±

, SREQ

±

, SACK

±

Symbol

Parameter

Min

Max

Unit

Test

Conditions

V

IH

Input high voltage

1.9

V

DD

V

V

IL

Input low voltage

V

SS

1.0

V

V

OH

1

1. TolerANT active negation enabled.

Output high voltage

2.0

V

DD

V

I

OH

= 7.0 mA

V

OL

Output low voltage

V

SS

0.5

V

48 mA

I

OZ

3-state leakage

10

10

µ

A

Table 4.6

Bidirectional SCSI Control Signals—SCD/, SIO/, SMSG/,
SBSY/, SATN/, SSEL/, SRST/, SCD

±

, SIO

±

, SMSG

±

,

SBSY

±

, SATN

±

, SSEL

±

, SRST

±

Symbol

Parameter

Min

Max

Unit

Test Conditions

V

IH

Input high voltage

1.9

V

DD

V

V

IL

Input low voltage

V

SS

1.0

V

V

OL

Output low voltage

V

SS

0.5

V

48 mA

I

OZ

3-state leakage

10

10

µ

A

Table 4.7

DIFFSENS SCSI Signal

Symbol Parameter

Min

Max

Unit

Test

Conditions

V

S

LVD sense voltage

0.7

1.9

V

V

IL

Single-ended sense voltage

V

SS

0.3

0.5

V

I

OZ

3-state leakage

10

10

µ

A