Appendix e, System testing and maintenance, Appendix e – system testing and maintenance – RISCO Group LightSYS User Manual
Page 49
![background image](https://www.manualsdir.com/files/858729/content/doc049.png)
Page 49
LightSYS User Manual
Appendix E – System Testing and Maintenance
The LightSYS should be tested once a week. In addition, the system should be
checked by a qualified technician at least every 3 years. Your weekly test should
include
:
System arming
System disarming
Creating an alarm
Testing the zones in the system through a Walk Test, allowing you to open and
then close each protected door and window while listening for the keypad to beep
confirming its operation
To perform a Walk Test:
1.
Make sure the system is disarmed.
2.
Press
and enter your code followed by
.
3.
Using the arrow keys, scroll to the option Maintenance and press
.
4.
Select Walk Test and press
.
5.
Select Full Walk test and press
.
6.
A beep is heard and the following display appears:
MAKE WALK TEST
AND HIT ANY KEY
Walk throughout the protected area and make sure you test every zone in the
system. You have 60 minutes to perform the test.
7.
When done, press any key. A list of the tripped zones during the walk test
appears. Use the arrow keypad's keys to scroll through the list of the zones
logged during the test
8.
Press
to confirm and exit the walk test mode.