2 mechanical data – KACO blueplanet gridsave eco 5.0 TR1 User Manual
Page 15

Technical Data
Operating instructions for blueplanet-gridsave eco_EN
Page 15
General electrical data
Max. efficiency [%]
96
No-load losses [W]
8
Safety
IEC 62040-1-1: 2002
Electromagnetic compatibility (EMC)
EN 61000.6.3:2007
Grid
Using the "Powador-protect" measurement and control unit*
According to overview of certifications
(download area: Kaco-newenergy.com)
Table 1:
Electrical data
4.2
Mechanical data
Display
LED, acoustic warning signals
Interfaces
USB, RS485, RS232, Ethernet via
external interface converter*
Connection for battery/inverter: Line*
max. 5 m at 50 mm² / 10 m at 70 mm²
Connection for battery/inverter:
Circuit breaker*
2-pole, 160 A
Ambient temperature [°C]
-10 to +60
Protection class
IP43
Cooling
Fan
H x W x D [mm]
690 x 375 x 220
Weight [kg]
40
System package * (optional)
•
Lead battery system, including connection set
•
External measurement unit for intrinsic consumption optimisation, 3-phase
•
Mains monitoring and system protection
•
Installation material (circuit breaker, residual current breaker)
Solar inverter** (compatible) (not included)
Please note the overview of compatible inverters for this purpose on our website
(http://kaco-newenergy.com/download/energy-systems-technology/energy-storage-systems/)
Table 2:
Mechanical data
* optionally available
** not included, update may be required for compatibility