Grid Under Frequency

F33

Under frequency on the grid side

CB20(Grid SW) Trip

F34

CB20 (AC Disconnect/Grid circuit breaker) was tripped during

operation

Reserved

F35~F39

Reserved

Parameters Version Error

F40

Different version between the NVSRAM parameter table and

the program parameter table

Flash Memory Failure

F41

C6000 DSP program flash memory failure in XCU (main

control) board

FPGA Failure

F42

FPGA failure in XCU (main control) board

DSP28x Failure

F43

F2000 DSP failure in XCU (main control) board

ADC Failure

F44

ADC block failure in XCU (main control) board

Reserved

F45~F49

Reserved

Emergency Stop

F50

A door is open

Cabinet Over Temp.

F51

Temperature of cabinet is too high. Inverter has stopped

operation