Configuration and operation, Lock-out power, Sw version displays the installed software version – KACO blueplanet 5.0 - 9.0 TL3 User Manual
Page 40

EN
EN
Configuration and Operation
Page 40
Operating Manual KACO blueplanet 5.0TL3 - 9.0TL3
Coun-
try-spec.
setting
menu
level
Display/
setting
Action in this menu/meaning
GB, IT, AT,
CH, KR, PL
0
1
2
3
2
Q(U) 5 Supports
Open the menu: Press the right arrow button or the
OK button.
0
1
2
3
3
Lock-in power
Power range set as % of rated power, in which the
network support process is active.
0
1
2
3
3
Lock-out power
0
1
2
3
3
Time constant
Set the response speed of the control.
0
1
2
3
3
Number of support
points
Specify the number of support points for the idle
power characteristic curve.
0
1
2
3
3
1., 2. ...Support
point
Specify the support points for voltage, power and
nature of the phase shift
GB, IT, KR
0
1
2
3
2
Q(U) 2-point
Open the menu: Press the right arrow button or the
OK button.
0
1
2
3
3
Lock-in power
Power range set as % of rated power, in which the
network support process is active.
0
1
2
3
3
Lock-out power
0
1
2
3
3
Time constant
Set the response speed of the control.
0
1
2
3
3
1.-4. Support point
Specify the support points for voltage, power and
nature of the phase shift
DE-NSp, BE,
CH
0
1
2
3
1
Line error
Display of grid faults.
To show the last 5 grid fault messages, select the
“Display” key.
DE, GB, AT,
CH
0
1
2
3
1
Protection param-
eters
Display of essential protection parameters.
To show the protection parameters, select the “Dis-
play” key.
IT
0
1
2
3
1
SPI
Provides the option of activating or confi guring the
specifi c "System Protection Interface" for Italian.
(Expansion module required!)
0
1
2
3
0
"Information"
menu
Open the menu: Press the right arrow button or the
OK button.
0
1
2
3
1
Inv. type
Displays the type designation of the inverter.
If feed-in power is actively limited: display maximum
power in kW.
0
1
2
3
1
SW version
Displays the installed software version.
0
1
2
3
1
Serial no.
Displays the serial number of the inverter.
0
1
2
3
1
Display country
Displays the selected country setting.
Optional: Displays the grid type if a grid type has been
selected.
0
1
2
3
0
"Manufacturer"
menu
The display shows information about the unit manufac-
turer.