Configuration and operation – KACO blueplanet 5.0 - 9.0 TL3 User Manual

Page 39

background image

EN

Configuration and Operation

Operating Manual KACO blueplanet 5.0TL3 - 9.0TL3

Page 39

Coun-

try-spec.

setting

menu

level

Display/

setting

Action in this menu/meaning

0

1

2

3

1

Powador-protect

Confi gures the support for grid shutdown by a Powador
protect connected to the digital input of the inverter.

↻ For Auto/On: A Powador protect is operating in

the photovoltaic system and is connected to the
inverter at the digital input/output.

 Auto: The inverter automatically detects a Pow-

ador-protect integrated into the photovoltaic
system.

 On: The digital signal of the Powador protect must

be present to the digital input of the inverter for the
inverter to start with feed-in.

 Off : The inverter does not check whether a Powador

protect is integrated in the photovoltaic system.

0

1

2

3

1

Iso.resistor

 Set threshold value (in 1 kOhm steps) at which the

insulation monitor reports a fault.

DE, CH, BE,

FR, GB, IL, IT,

AT, PL, RU, ES,

KR, TH, ZA

0

1

2

3

1

Reactive power

 Open the menu: Press the right arrow button or the

OK button.

 Activating idle power process: select process and

press OK. The active process is highlighted.

0

1

2

3

2

cos-phi specifi ca-

tion

 Confi gure power factor.

 If a power factor is selected which is not equal to

1: Select the type of phase shift (under-excited/
over-excited).

DE, FR, GB, IL,

IT, AT, PL, RU,

ES, KR, TH,

UD, ZA

0

1

2

3

2

Q const.

 Set the idle power Q (in %) to a fi xed value.

 Select the type of phase shift (under-excited/

over-excited).

DE, CH, BE,

GB, IT, AT, PL

ES, KR, UD

0

1

2

3

2

cos-phi(P/Pn)

 Open the menu: Press the right arrow button or the

OK button.

GB, IT, AT, ES,

KR

0

1

2

3

3

Lock-in voltage

 Power range set as % of rated voltage, where the

network support process is active.

0

1

2

3

3

Lock-out

voltage

DE, BE, FR,

GB, IL, IT, AT,

PL, RU, ES,

KR, TH, UD

0

1

2

3

3

Number of

nodes

This option defi nes how many support points can be
defi ned in the subsequent menu. The maximum number
of confi gurable support points depends on the selected
grid type.

 Specify the number of support points for the idle

power characteristic curve.

0

1

2

3

3

1., 2. ...Support

point

 Specify the power factor for the 1st, 2nd (etc.) sup-

port point

 If a power factor not equal to 0 is selected: Select the

type of phase shift (under-excited/over-excited).