Configuration and Operation

Page 38

Operating Manual KACO blueplanet 5.0TL3 - 9.0TL3

Coun-

try-spec.

setting

menu

level

Display/

setting

Action in this menu/meaning

DE, FR, GB,

IN, IT, AT, PL,

RU, ES, TH,

ZA, UD

0

1

2

3

1

Overfreq. shutd.

 Set limit value for overfrequency shutdown.

0

1

2

3

1

Underfreq. shutd.

 Set limit value for the underfrequency shutdown.

FR, IL, IN, IT,

AT, PL, RU,

TH, ZA, UD

0

1

2

3

1

Activation

condition

The inverter checks mains voltage and frequency. The
grid feed operation begins if the measured values are
within the set ranges.

 Set minimum and maximum values for the switch-

ing on.

DE, CH, BE,

FR, GB, IL, IN,
IT, AT, PL, RU,

ES, TH, ZA,

UD

0

1

2

3

1

Connect time

 Set period for grid observation (in seconds) when

switching on and reconnection after a fault.

IL, IT, ZA

0

1

2

3

1

P(f) Gradient

 Set gradient of power limit function with increasing

frequency in % / Hz. This percentage relates to the
nominal frequency of 50 Hz

0

1

2

3

1

P(f) thresholds

 Set the frequency thresholds for activating and

deactivating the power limitation in Hz.

0

1

2

3

1

DC connection

 Select between automatic detection and manual

setting.

 Note the connection examples! (See section 7.5.3 on

page 22)

0

1

2

3

1

DC starting volt.

The inverter begins feed-in as soon as this DC voltage is

present.

 Set the starting voltage.

0

1

2

3

1

Const. volt. ctrl.

Lets you deactivate the MPP seek mode in order to oper-
ate the inverter with a constant DC voltage.

 Activate or deactivate function.

 Set value for constant voltage control (200 - 800 V).

NOTE: For voltages below the minimal MPP voltage the

possible input power is reduced. The input current is
limited here to 11A per input.

0

1

2

3

1

Power

limitation

The output power of the inverter can be set perma-
nently to a lower value than the maximum output
power by the internal power limiting. This may be nec-
essary in order to limit the maximum power rating of
the system at the grid connection point, upon the grid
operator's request.

The value can be protected from the very fi rst output
limitation entry. After setting a limitation, the value can
only be changed by entering a device-specifi c password.

1.

Activate password protection if necessary.

2. Specify the activation status.

3. Specify the limit value for maximum feed-in power.

4. Confi rm the entry with the OK button.