2 ) lio-02 module connectors, Lio-01/lio-02 module – Yaskawa MP2000 Series I/O Module User Manual User Manual
Page 41

2.2 Specifications of LIO-01/LIO-02 Module Connections
2.2.6 LIO-01/LIO-02 Module Connections
41
2
LIO-01/LIO-02 Module
( 2 ) LIO-02 Module Connectors
The pins No. A5 and B5, and the pins No. A6 and B6 are internally connected. Connect them externally as well.
+5V
0V
+5V
Pulse input
Latch input
or phase-Z
pulse
5V
A2
B2
A4
PB
PBL
GND
PC
PCL5
PCL12
A3
A24
B24
B3
B4
PA
PAL
A1
B1
DI_COM0
DI_01
DI_02
DI_03
DI_04
DI_05
DI_06
DI_07
DI_00
A23
B22
A22
B21
A21
B20
A20
B19
A19
Digital input
R
R
DI_COM1
DI_09
DI_10
DI_11
DI_12
DI_13
DI_14
DI_15
DI_08
B23
B18
A18
B17
A17
B16
A16
B15
A15
R
R
R
R
R
R
R
Fuse
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
Fuse
DO_24V
DO_24V
DO_00
DO_01
DO_02
DO_03
DO_04
DO_05
DO_06
DO_07
DO_08
DO_09
DO_10
DO_11
DO_12
DO_13
DO_14
DO_15
DO_COM
DO_COM
B6
A6
B14
A14
B13
A13
B12
A12
B11
A11
B10
A10
B9
A9
B8
A8
B7
A7
A5
B5
R
Digital input
Digital output
Fuse blown
detection circuit
Pulse generator
Phase A
Phase B
Latch input or
phase-Z pulse
24 VDC
External input
signals
24 VDC
External input
signals
24 VDC
External output
signals
A fuse is inserted in the output common line of the LIO-02 Module for circuit protection. However, the fuse
may not be blown out in the cases such as layer shorts in outputs. To ensecure the circuit protection, provide