Model
Terminal
Recomm. Gauge
AWG, kcmil
Wire Range
AWG, kcmil
Screw
Size
Tightening Torque
N·m (lb. in.)
2A0088
<1>
R/L1, S/L2, T/L3
2
8 to 2/0
M8
5.4 to 6.0
(48 to 53)
U/T1, V/T2, W/T3
2
-M, +M
–
–
2A0114
<1>
R/L1, S/L2, T/L3
1/0
8 to 2/0
M8
5.4 to 6.0
(48 to 53)
U/T1, V/T2, W/T3
1/0
-M, +M
–
–
2A0143
<1>
R/L1, S/L2, T/L3
3 × 2
1/0 to 3/0
M8
13.5 to 15.0
(120 to 133)
U/T1, V/T2, W/T3
3 × 2
-M, +M
–
–
2A0169
<1>
R/L1, S/L2, T/L3
2 × 2
1/0 to 3/0
M8
13.5 to 15.0
(120 to 133)
U/T1, V/T2, W/T3
2 × 2
-M, +M
–
–
2A0211
<1>
R/L1, S/L2, T/L3
1/0 × 2
1/0 to 3/0
M8
13.5 to 15.0
(120 to 133)
U/T1, V/T2, W/T3
1/0 × 2
-M, +M
–
–
2A0273
<1>
R/L1, S/L2, T/L3
2/0 × 2
1/0 to 4/0
M10
27.0 to 30.0
(239 to 266)
U/T1, V/T2, W/T3
2/0 × 2
-M, +M
–
–
M8
13.5 to 15.0
(120 to 133)
2A0343
<1>
R/L1, S/L2, T/L3
4/0 × 2
3/0 to 350
M12
32.0 to 40.0
(283 to 354)
U/T1, V/T2, W/T3
4/0 × 2
–, +1
–
+3
–
M10
18.0 to 23.0
(159 to 204)
–
M12
32.0 to 40.0
(283 to 354)
2A0396
<1>
R/L1, S/L2, T/L3
250 × 2
3/0 to 350
M12
32.0 to 40.0
(283 to 354)
U/T1, V/T2, W/T3
250 × 2
–, +1
–
+3
–
M10
18.0 to 23.0
(159 to 204)
–
M12
32.0 to 40.0
(283 to 354)
<1> Drive models 2A0046 to 2A0396 require the use of closed-loop crimp terminals for UL/cUL compliance. Use only the tools recommended by the
terminal manufacturer for crimping.
3.8 Main Circuit Wiring
84