2 general description, Z1000 model selection, General description – Yaskawa AC Drive Z1000 User Manual
Page 25

1.2 General Description
u
Z1000 Model Selection
for drive selection depending on the motor power.
Note:
The models and capacities in shown here are based on standard settings and operation conditions. Higher carrier frequencies and higher
ambient temperatures require derating.
Table 1.1 Z1000 Models
Motor Capacity kW (HP)
Three-Phase 200 V Class
Model CIMR-Zo
Rated Output Current (A)
2.2 (3)
2A0011
10.6
<1>
3.7 (5)
2A0017
16.7
<1>
5.5 (7.5)
2A0024
24.2
<1>
7.5 (10)
2A0031
30.8
<1>
11 (15)
2A0046
46.2
<1>
15 (20)
2A0059
59.4
<1>
18.5 (25)
2A0075
74.8
<1>
22 (30)
2A0088
88
<1>
30 (40)
2A0114
114
<1>
37 (50)
2A0143
143
<1>
45 (60)
2A0169
169
<1>
55 (75)
2A0211
211
<1>
75 (100)
2A0273
273
<1>
90 (125)
2A0343
343
<2>
110 (150)
2A0396
396
<2>
<1> Assumes the carrier frequency is set to 5 kHz.
<2> Assumes the carrier frequency is set to 2 kHz.
Motor Capacity kW (HP)
Three-Phase 400 V Class
Input Voltage < 460 V
Input Voltage ≥ 460 V
Model CIMR-Zo
Rated Output Current (A)
1.5 (2)
2.2 (3)
4A0005
4.8
<1>
3.0 (4)
3.7 (5)
4A0008
7.6
<1>
4.0 (5)
5.5 (7.5)
4A0011
11
<1>
5.5 (7.5)
7.5 (10)
4A0014
14
<1>
7.5 (10)
11 (15)
4A0021
21
<1>
11 (15)
15 (20)
4A0027
27
<1>
15 (20)
18.5 (25)
4A0034
34
<1>
18.5 (25)
22 (30)
4A0040
40
<1>
22 (30)
30 (40)
4A0052
52
<1>
30 (40)
37 (50)
4A0065
65
<1>
37 (50)
45 (60)
4A0077
77
<1>
45 (60)
55 (75)
4A0096
96
<1>
55 (75)
75 (100)
4A0124
124
<1>
75 (100)
90 (125)
4A0156
156
<1>
90 (125)
110 (150)
4A0180
180
<1>
110 (150)
150 (200)
4A0240
240
<2>
160 (220)
185 (250)
4A0302
302
<2>
1.2 General Description
YASKAWA ELECTRIC TOEP C710616 45E YASKAWA AC Drive – Z1000 User Manual
25
1
Receiving