Connection to busbars

1. Open the Sunny Central as described in section 10.1.
2. Position the cable lug or lugs on the busbar.
3. Insert the lock washers and screws into the holes.
4. Tighten the screw with a nut in a clockwise direction using a torque of 55 ft.-lbs.
5. Connect all grounding cables as described above.
6. The DC– cables are connected.