beautypg.com

SMA SC 200 User Manual

Page 92

background image

Troubleshooting and Problem Solving

SMA Solar Technology AG

92

SC-BEN100262

User Manual

420

Error text:
ADAPSCP Overtemperature

Error type 3

Cause of error:
Heat sink temperature is too high (hardware threshold)
Corrective measures:

• Check that the cooling fans of the inverter bridge are working properly.
• Clean soiled air inlet or heat sink.
• Ambient or cooling air temperature too high.
• If this error occurs frequently, contact the SMA Serviceline.

421

Error text:
ADAPSCP Overvoltage DC Voltage link

Error type 2

Cause of error:
DC voltage is too high on the generator side (hardware threshold).
Corrective measures:

• Immediately disconnect the PV generator from the Sunny Central! Danger of damage

to the Sunny Central!

• Check DC voltage.
• Check module wiring and system design.

No.

Description