SMA SC 200 User Manual
Page 91
![background image](https://www.manualsdir.com/files/818949/content/doc091.png)
SMA Solar Technology AG
Troubleshooting and Problem Solving
User Manual
SC-BEN100262
91
409
Error text:
IGBT Stack Temperature
Error type 3
Cause of error:
Heat sink temperature is too high (software).
Corrective measures:
• Check that the cooling fans of the inverter bridge are working properly.
• Clean soiled air inlet or heat sink.
• Ambient or cooling air temperature too high.
• If this error occurs frequently, contact the SMA Serviceline.
410
Error text:
IGBT Stack Error Sum
Error type 3
Cause of error:
Internal inverter bridge fault (e.g. DC overvoltage, overtemperature, defective driver,
overcurrent).
Corrective measures:
If this error occurs frequently, contact the SMA Serviceline.
411
Error text:
IGBT-Overcurrent or UVW-Phase Error ADAPSCP
Error type 3
Cause of error:
Internal inverter bridge fault.
Corrective measures:
If this error occurs frequently, contact the SMA Serviceline.
412
Error text:
Overcurrent
Error type 3
Cause of error:
Internal inverter bridge fault.
Corrective measures:
If this error occurs frequently, contact the SMA Serviceline.