Error text:
Team contactor remain opened

Error type 1

Cause of error:
The team contactor does not trigger.
Corrective measures:

• Check the triggering of the team contactor.
• Check the feedback contact of the isolation contactor.
• Check whether the team current monitoring system has tripped.

587

Error text:
Team contactor remain closed

Error type 1

Cause of error:
The team contactor has not switched off. The switching contacts may have got stuck.
Corrective measures:

• Check the triggering of the team contactor.
• Check the contact position of the team contactor.
• Contact Sunny Central Service.

588

Error text:
Team contactor was opened

Error type 1

Cause of error:
The team contactor has been switched off by the team current monitoring system.
Corrective measures:

• Check the triggering of the team contactor.
• Check the team current monitoring system (settings, fault).
• Check the team current; it may be too high due to asymmetrical current distribution.
• Contact Sunny Central Service.

601

Error text:
Defective default Effective power

Error type 1

Cause of error:
The current value at the analog input is not within the permissible range.
Corrective measures:

• Check the analog input.