SMA SC 200 User Manual
Page 84
![background image](https://www.manualsdir.com/files/818949/content/doc084.png)
Troubleshooting and Problem Solving
SMA Solar Technology AG
84
SC-BEN100262
User Manual
586
Error text:
Team contactor remain opened
Error type 1
Cause of error:
The team contactor does not trigger.
Corrective measures:
• Check the triggering of the team contactor.
• Check the feedback contact of the isolation contactor.
• Check whether the team current monitoring system has tripped.
587
Error text:
Team contactor remain closed
Error type 1
Cause of error:
The team contactor has not switched off. The switching contacts may have got stuck.
Corrective measures:
• Check the triggering of the team contactor.
• Check the contact position of the team contactor.
• Contact Sunny Central Service.
588
Error text:
Team contactor was opened
Error type 1
Cause of error:
The team contactor has been switched off by the team current monitoring system.
Corrective measures:
• Check the triggering of the team contactor.
• Check the team current monitoring system (settings, fault).
• Check the team current; it may be too high due to asymmetrical current distribution.
• Contact Sunny Central Service.
601
Error text:
Defective default Effective power
Error type 1
Cause of error:
The current value at the analog input is not within the permissible range.
Corrective measures:
• Check the analog input.
No.