2 sunny boy 3000tl single tracker, Sunny boy 3000tl single tracker – SMA SB 2500TL-21 Installation User Manual
Page 86

Technical Data
SMA Solar Technology AG
86
SB25-30TLST-21-IA-en-13
Installation Manual
* Depending on country setting
Efficiency
13.1.2 Sunny Boy 3000TL Single Tracker
DC Input
* The maximum open-circuit voltage that can occur at -10°C cell temperature must not exceed the maximum input voltage.
AC Output
Feed-in phases
1
Connection phases
1
Overvoltage category as per IEC 60664-1
III
Maximum efficiency, η
max
97.0%
European weighted efficiency, η
EU
95.8%
Maximum DC power at cos φ = 1
3,200 W
Maximum input voltage*
750 V
MPP voltage range
213 V to 500 V
Rated input voltage
400 V
Minimum input voltage
125 V
Initial input voltage
150 V
Maximum input current
15 A
Maximum input current per string
15 A
Number of independent MPP inputs
1
Strings per MPP input
2
Rated power at 230 V, 50 Hz
3,000 W
Maximum apparent AC power cos φ = 1
3,000 VA
Rated grid voltage
230 V
AC nominal voltage
220 V / 230 V / 240 V
AC voltage range*
180 V to 280 V
Nominal AC current at 220 V
13.6 A
Nominal AC current at 230 V
13.1 A
Nominal AC current at 240 V
12.5 A
Maximum output current
14.6 A
Maximum output current in case of faults
14.6 A
Total harmonic factor of output current at
AC total harmonic factor < 2%,
AC power > 0.5 nominal AC power
≤ 4%
Rated mains frequency
50 Hz