beautypg.com

8 opening and closing, 1 safety, Opening and closing – SMA SB 2500TL-21 Installation User Manual

Page 56: Safety

background image

Opening and Closing

SMA Solar Technology AG

56

SB25-30TLST-21-IA-en-13

Installation Manual

8 Opening and Closing

8.1 Safety

DANGER!
Danger to life due to high voltages in the inverter

Before opening the inverter, observe the following:

• Disconnect the miniature circuit-breaker and secure against reconnection.
• If a multi-function relay is connected, disconnect its supply voltage and ensure that it

cannot be reconnected.

DANGER!
Danger to life due to electric shock.

If the DC connectors are pulled out without first disconnecting the ESS or switching off the
DC switch-disconnector, a dangerous electric arc can occur.

• Disconnect the ESS or switch off the DC

switch-disconnector first.

• Then, open the lower enclosure lid and

remove the DC connectors.

NOTICE!
Electrostatic discharge can damage the inverter

The internal components of the inverter can be irreparably damaged by electrostatic
discharge.

• Earth yourself before touching any components.