3 mounting the inverter, Mounting the inverter – SMA SB 2500TL-21 Installation User Manual
Page 25

SMA Solar Technology AG
Mounting
Installation Manual
SB25-30TLST-21-IA-en-13
25
5.3 Mounting the Inverter
Additionally required mounting material (not included in the scope of delivery):
– 3 screws (diameter: at least 6 mm)
– 3 wall plugs
– 3 washers (external diameter: at least 18 mm)
1. Use the wall mounting bracket as a drilling template and mark the positions of the drill holes.
Number of drill holes to use
• When mounting onto the wall, use at least two of the horizontal holes and the lower
centre hole.
• Use the two holes in the centre when mounting the device on a pillar.
490 mm
335 mm
175 mm
80 mm
55 mm
33 mm
175 mm
65 mm
45 mm
30 mm
9 mm
9 mm x 18 mm
70 mm
70 mm
31
mm
25
mm
57mm
98 mm
133 mm
This manual is related to the following products: