Mounting

SMA Solar Technology AG

24

SB25-30TLST-21-IA-en-13

Installation Manual

• Mount vertically or tilted backwards by max. 15°.
• The connection area must face downwards.
• Never mount the device with a forward tilt.
• Never mount the device with a sideways tilt.
• Do not mount horizontally.
• Mount at eye level in order that operating states can be read at all times.
• The ambient temperature should be below 40°C to ensure optimum operation.
• Do not expose the inverter to direct solar irradiation as this can cause excessive heating and

thus power reduction.

• In living areas, do not mount the unit on plasterboard walls or similar in order to avoid audible

vibrations. When in use, the inverter emits noises which may be perceived as a nuisance in a
living area.

• Observe the recommended minimum clearances to

the walls as well as to other inverters and objects as
shown in the diagram. This will ensure sufficient
heat dissipation and gives you enough space to
unplug the ESS.

• If multiple inverters are mounted in areas with high

ambient temperatures, increase the clearances
between the inverters and ensure an adequate
fresh-air supply. This will prevent a reduction in
inverter power as a result of high temperatures
(details on temperature derating can be found in
the Technical Information "Temperature Derating"
at www.SMA.de/en). A fan for connection to the
inverter is available as an accessory
(see Section 14 "Accessories" (page 91)).

500 mm

100 mm

100 mm

50

mm

300 mm