beautypg.com

1 checking the country standard, Checking the country standard – SMA SB 2500TL-21 Installation User Manual

Page 45

background image

SMA Solar Technology AG

Electrical Connection

Installation Manual

SB25-30TLST-21-IA-en-13

45

6.5.1 Checking the Country Standard

Make sure that the inverter is set to the country of installation.
Before commissioning:

• Check that the country standard of the inverter is correct by comparing the default settings of

the inverter listed on the supplementary sheet provided.

After commissioning:

• Check that the country standard is correct on the basis of the display message during

(re-)commissioning (see Section 7 "Commissioning" (page 52)).

• Check whether the country standard is correct by tapping the display twice and viewing the

display messages of the start-up phase again.
or

• Check that the country standard is correct using the "SMA grid guard" measuring channel via

a communication product.

The settings of each country data set are specified in the operating parameters. The parameters can
be read using a communication product. The description of the operating parameters is available at
www.SMA.de/en in the category "Technical Description" of the respective inverter.

Display language
Once you have set the country standard, you can always set the display language later
using rotary switch B. However, you have to then set rotary switch A to "0" in order to keep
the country data set.

(A) (B) Country data set

Display language

Grid Guard
protection

Country

0

0

default setting

default setting

dependent on
parameter set

dependent on
parameter set

0

1

retained

English

dependent on
parameter set

dependent on
parameter set

0

2

retained

German

dependent on
parameter set

dependent on
parameter set

0

3

retained

French

dependent on
parameter set

dependent on
parameter set

0

4

retained

Spanish

dependent on
parameter set

dependent on
parameter set

0

5

retained

Italian

dependent on
parameter set

dependent on
parameter set

0

6

retained

Greek

dependent on
parameter set

dependent on
parameter set

0

7

retained

Czech

dependent on
parameter set

dependent on
parameter set

This manual is related to the following products: