2 assembling the dc connectors, Assembling the dc connectors – SMA SB 2500TL-21 Installation User Manual

Page 36

background image

Electrical Connection

SMA Solar Technology AG

36

SB25-30TLST-21-IA-en-13

Installation Manual

6.4.2 Assembling the DC Connectors

All PV display module connection cables must be equipped with the DC connectors supplied before
connecting them to the inverter.
Assemble the DC connectors as described below. Be sure to observe the correct polarity.
The DC connectors are marked with the symbols "+" and " − ".

Cable Requirements

• Use a PV1-F cable.

Procedure

1. Lead the stripped cable all the way into the DC

connector.

2. Press the clamping bracket down until it audibly

snaps into place.

3. Ensure that the cable is correctly positioned:

Result

Measure

☑ If the stranded wires are visible in the

chamber of the clamping bracket, the cable
is correctly positioned.

• Proceed to step 4.