Installation Manual
SB25-30TLST-21-IA-en-13
23
5 Mounting
5.1 Safety
5.2 Selecting the Mounting Location
Take the following requirements into consideration when selecting the mounting location:
• The mounting location must be inaccessible to children.
• The mounting method and location must be suitable for the weight and dimensions of the
inverter (see Section 13 "Technical Data" (page 85)).
• Mount on a solid surface.
• The mounting location must be clear and safely accessible at all times without the use of
additional aids such as scaffolding or lifting platforms. Non-fulfillment of these criteria may
restrict execution of servicing.
DANGER!
Danger to life due to fire or explosions
Despite careful construction, electrical devices can cause fires.
• Do not mount the inverter on flammable construction materials.
• Do not mount the inverter in areas where highly flammable materials are stored.
• Do not mount the inverter in a potentially explosive atmosphere.
CAUTION!
Risk of burns due to hot enclosure parts
• Mount the inverter in such a way that it cannot be touched inadvertently during
operation.
CAUTION!
Risk of injury due to the heavy weight of the inverter
• When mounting, bear in mind that the inverter weighs approx. 23 kg.