beautypg.com

SMA SB 2500TL-21 Installation User Manual

Page 61

background image

SMA Solar Technology AG

Opening and Closing

Installation Manual

SB25-30TLST-21-IA-en-13

61

5. If an external DC switch-disconnector is in use, disconnect it.
6. If an ESS is used, check it for wear (see Section 9.3 "Checking the Electronic Solar Switch for

Wear" (page 62)), and plug it in firmly.

7. If a multi-function relay is connected, switch on the supply voltage to the relay.
8. Switch the miniature circuit-breaker on.
9. Check that the display and the LEDs are indicating

a normal operating state
(see Section 7 "Commissioning" (page 52)).

☑ The inverter is now closed and in operation.

NOTICE!
The ESS can be damaged if it is not connected correctly.

• Plug the ESS in securely.

The ESS handle must be flush with the
enclosure.

• Check that the ESS is securely in place.

This manual is related to the following products: