beautypg.com

1 explanation of the status symbols, 2 plant status, Explanation of the status symbols – SMA SUNNY WEBBOX User Manual

Page 42: Plant status

background image

Operation

SMA Solar Technology AG / SMA America, LLC

42

SWebBox-BA-en-36

User Manual

8.1.1 Explanation of the Status Symbols

This section explains the meanings of the various status symbols in the web interface of the
Sunny WebBox. The symbol of a Sunny Boy appears in each of the following examples.
The Sunny WebBox user interface shows other devices in the PV plant with corresponding symbols.

8.1.2 Plant Status

You can read the status of the entire PV plant under "Plant" in the "Status" table. If devices in the plant
have the status 'Error' or 'Warning', then the number of affected devices and the serial number of one
of the affected devices is shown next to the relevant symbol.

Symbol

Explanation
This symbol indicates that the inverter is operational and communicating with the
Sunny WebBox.

This symbol indicates that communication has been established with the
Sunny WebBox but that the inverter has an error.

This symbol is displayed in the following cases:

• The inverter is unable to communicate with the Sunny WebBox.
• A communication error has occurred with the inverter.
• It is nighttime and the inverter is switched off.

Item

Designation

A

Device with the status "Error"

B

Device with the status "Disturbance" or "Warning"