7 a dditional f unctions – HEIDENHAIN TNC 310 (286 140) User Manual
Page 183

171
HEIDENHAIN TNC 310
1
0.7 A
dditional
F
unctions
Group name, ID No.
Number
Index
System data
Limit switch, 230
1
–
Number of the active limit switch range
2
1 to 4
Negative coordinate limit switch in M91 system
Index 1 to 4: X-axis to IVth axis
3
1 to 4
Positive coordinate limit switch in M91 system
Index 1 to 4: X-axis to IVth axis
Positions in M91 system, 240
1
1 to 4
Nominal position; Index 1 to 4: X-axis to IVth axis
2
1 to 4
Last touch point
Index 1 to 4: X-axis to IVth axis
3
1 to 4
Active pole; Index 1 to 4: X-axis to axis IV axis
4
1 to 4
Center point of circle; Index 1 to 4: X-axis to IVth axis
5
1 to 4
Center point of circle for the last RND block
Index 1 to 4: X-axis to IVth axis
Positions in the input system, 270
1
1 to 4
Nominal position; Index 1 to 4: X-axis to IVth axis
2
1 to 4
Last touch point
Index 1 to 4: X-axis to IVth axis
3
1 to 4
Active pole; Index 1 to 4: X-axis to axis IV axis
4
1 to 4
Center point of circle; Index 1 to 4: X-axis to IVth axis
5
1 to 4
Center point of circle for the last RND block
Index 1 to 4: X-axis to IVth axis
TT 120 calibration data, 350
20
1
Center of probe contact in X-axis
2
Center of probe contact in Y-axis
3
Center of probe contact in Z axis
21
–
Probe contact radius
Example: Assign the value of the active scaling factor for the Z axis
to Q25.
55 FN18: SYSREAD Q25 = ID210 NR4 IDX3