Download the Configuration to Your SMS-6000 Router
1. Verify that there is a RS232 serial connection between one of the PC's
serial (COM) ports and the Master Frame's serial port.
NOTES:
Section 2 Installation, sub-section Configuring the Frame in the Series
6000 Compact Signal Management System manual, covers the Installation and
set-up of the frames.
Serial I/F links must be set for RS232.
2. From the SMS-6000 Configuration Editor, verify the
a. Select
OPTIONS
.
b. Select
COMM PARAMETERS
.
c. Settings should be:
Com Port: is the Com Port actually connected
Com Speed: 9600 baud
Parity: none
Data Bits: 8+1
3. The configured addresses for Frames and Panels match their actual
rotary hex switch setting.
If you change this setting, press the Reset button on the Frame or Panel.
NOTE:
Compare the Frame and Panel rotary hex addresses to their configured
addresses by checking the Frame Actions and Panel Actions windows
4. One and only one control board, on one and only one frame, is set to be
the Master.
The dip switch settings on the Master are Switch 1-up, Switch 2-down,
Switch 3-down, and Switch 4-up. On Slave boards all dip switches are
set in the up position.
Reset frame after changing dip switch settings.