Configuring Remote Control Panels
Configuring Remote Control Panels
The main software configuration determines how each panel functions.
However there are a few functions set on the panels by the user. This
section describes how to alter them.
Refer to Figure 2-7 through Figure 2-10 on page 18 for the front view of the
control panels.
NOTE:
The rotary hex and DIP switches are read only at power up or following a
RESET. If you make any changes you must press the RESET button so that the
new settings are acted upon.
Panel Address
Panels connected directly to the Quick-Link are fitted with a rotary hex
switch to set the unique address of the panel.
The user must configure these addresses before operating the system.
If you have more than one panel in your system then you must set each
panel to have a different code. If this is not done then the panel
communications down the coaxial Quick-Link cannot function properly.
Also the master unit will not be able to download a configuration for the
panels. Normally equipment is shipped with these addresses set
sequentially to match the number of panels in the system.
Buzzer
Most panels are fitted with a buzzer to provide warnings when certain
buttons are pressed on an optional locally-mounted control panel. This can
be enabled or disabled by moving a jumper link adjacent to the buzzer.