beautypg.com

Data routing, Inputs, Crosspoints – Grass Valley SMS-6000 Series User Manual

Page 24: Outputs, Data routing -7, Inputs -7 crosspoints -7 outputs -7

background image

1-7

Data Routing

Data Routing

A solid state router is used mainly for machine control, such as to assign
VTRs to an edit controller. RS422 uses four wires with one pair used for the
transmit signal and the other pair for the receive, so the router handles both
a forward and a reverse signal path through the matrix. It can be supplied
equipped for 8x8 or 16x16.

Inputs

The RS422 inputs are terminated in 110

. Inputs 1–8 are installed on the

main matrix module and Inputs 9–16 on a submodule.

Crosspoints

A single crosspoint chip has the capacity to switch 16 inputs to the 16
outputs.

Outputs

The output drivers are designed to drive 110

lines.

The module has the capability of 16 outputs, but for systems with 8 outputs