Lock types, Save the configuration, Save the configuration -23 – Grass Valley SMS-6000 Series User Manual
Page 86: Lock type

159398-00 Software Ver1.0
Copyright © Tektronix, Inc., Grass Valley Products
3-23
Configuring the SMS-6000 Router
Lock Types
MiniXY and XY Panels have: None, PanelLock, and DestLock
16BPS and 32BPS Panels have: None, PanelLock, DestLock, and 2-Finger
Enable
■
DestLock
—This lock is active only for a particular Destination. To
select it:
a. The
DESTINATION
to be locked is made active
b. The
LOCK
button is pushed.
Now, attempting to select any button on the originating panel (other
than the
LOCK
button or
DESTINATION
select button) will result in a beep
and have no effect. The operator has the choice of making any or all
Destinations locked on the originating panel. All other panels on the Q-
link are unaffected.
■
PanelLock
—This locks the panel originating the lock for all
destinations. Attempting to select any button on the panel (except
LOCK
) results in a beep and no effect. All other panels on the Q-link are
unaffected.
■
2-Finger Enable
—To do a Take, hold down the
LOCK
button with 1
finger & press the
SOURCE
button with another.
Save the Configuration
1. Select
FILE
.
2. Select
SAVE
(for a edited file) or
SAVE
AS
(for a new file).
3. Enter File name (if needed for a new file).
4. Verify that Directory/Drive is the one where you want to save the file.
5. Verify that Save File as Type says Config files.
6. Click on
OK
.
Figure 3-17. Save Configuration Windows