6. Maintenance

Chapter 6 provides maintenance instructions. It discusses the following topics:

General Maintenance

Fuse Replacement

Indicator LEDs

Air Flow

Battery Replacement

Troubleshooting

Obtaining Service

General Maintenance

The NV8256-Plus does not require any periodic electrical or physical maintenance. Other than
cleaning the fan air intake filter, all that is required is periodic inspection of the system to make sure
no failures have occurred.

It is recommended that the system’s indicator LEDs be checked on a regular basis to ensure that the
system is operating properly. (See

Indicator LEDs

on page 60.) It is also a good idea to regularly

make sure cooling air flow to the power supply fans is unobstructed.

Fuse Replacement

Fuses are located on each of the frame modules. If a problem occurs on a module, it is a good to
check the fuses. The following table lists the fuses on each module:

Caution

Only qualified service personnel should perform procedures in this section.

Location

Fuse Value

Power supply AC line fuse

8 Amp, 5

× 20 mm, slow-blow

Control card DC fuse

1 Amp, auto reset (not user serviceable)

Crosspoint card

1 Amp, auto reset (not user serviceable)

Warning

Dangerous voltages are present at the rear AC power connector and on the power
supply module. Take precautions to prevent electric shock: Do not touch exposed
wires or connecting pins.